TM 9-2320-285-24-2
3-17. TRANSMISSION MAINTENANCE (CONT)
e. Modulator Assembly (cont).
STEP
LOCATION
ITEM
ACTION
REMARKS
CLEANING (cont)
2
(cont)
WARNING
Dry cleaning solvent (P-D-680), used to clean parts is toxic and flammable. Wear protective goggles and gloves and
use only in a well ventilated area. Avoid contact with skin, eyes, and clothes and don't breathe vapors. Do not use
near open flame or excessive heat and don't smoke when using it. Failure to do so could cause serious injury. If
you become dizzy while using cleaning solvent, get fresh air and medical attention immediately. If contact with skin
or clothes is made, flush with large amounts of water. If contact with eyes is made, wash eyes with water and obtain
medical aid
immediately.
Compressed air must not exceed 30 psi. Wear safety glasses when drying parts with compressed air. Failure to do
so could cause serious injury to eyes and possible blindness. If you hurt your eyes or if a foreign object is blown into
your eyes, seek medical attention immediately.
c. All other parts
Clean
Use cleaning solvent P-D-680;
dry using compressed air
INSPECTION
3
a. Gasket (6) and
Inspect
Replace if cut, cracked, or
O-ring (14)or deteriorated
b. Spring (10)
Inspect
Replace if cracked, deformed,
or permanently set
c. Cable (13)
Inspect
Replace if kinked, binding,
or otherwise damaged
d. All other parts
Inspect
Replace if cracked, broken,
or threads damaged
REASSEMBLY
4
Modulator
a. O-ring (14)
a. Position
On cable (13)
cable
b. Lubricate
Apply thin film of petrola tum
assembly
to outside of O-ring
3-123
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |