3-17. TRANSMISSION MAINTENANCE (CONT)
e. Modulator Assembly (cont).
STEP
LOCATION
ITEM
ACTION
REMARKS
DISASSEMBLY
1
Modulator
a. Retaining ring
Remove
Use retaining ring pliers
cable(1)
assembly
b. Plunger (2)
Remove
c. Five capscrews
Remove
(3) and lock
washers (4)
d. Cover (5)
Remove
e. Gasket (6)
Remove
f. Cable (13) core
Retract
Pull at free end of cable
g. Pin (7)
Remove
Pull from lever (8) and bore
in housing; note position
of lever for reassembly
h. Lever (8) and
a. Remove as
Rotate lever and retainer
retainer (9)
assembly
outward about cable core
through 90 degrees; then
compress spring to cable
end of housing to remove
b. Separate
NOTE
Keep cable (13) core retracted when performing the following step.
i. Spring (10) and
a. Remove as
Compress thimble and spring
thimble (11)
assembly
away from cable (13) to
remove
b. Separate
j. Setscrew (12)
Remove
Only if necessary to replace
cable (13), O-ring (14), or
housing (15)
k. Cable (13)
Remove
Twist housing (15) slightly
and pull cable to remove
l. O-ring (14)Remove
CLEANING
2
a. Gasket (6) and
Clean
Use clean, dry cloth only
O-ring (14)
b. Cable (13)
Clean
Use clean cloth moistened
with detergent; dry using
clean cloths
3-122