 |  TM 9-2320-285-24-1 2-30. 24V INVERTER MAINTENANCE (CONT) STEP LOCATION ITEM ACTION REMARKS INSTALLATION (cont) 9 g. 12-volt recep- Position In rear hood enclosure; align (cont) tacle (20) receptacle mounting holes with cover hinge at the top h. Two capscrews Install and (19), lock tighten washers (18), and nuts (17) i. Boot (16) Install Push onto 7-wire cable (29), small diameter end first j. 7-wire cable Connect To 12-volt receptacle (20) as (29) leads tagged k. Seven screws Install and (15) tighten l. Boot (16) Slide Onto 12-volt receptacle (20) forward m. Electrical tape Install Wrap new electrical tape around 7-wire cable (29) and 12-volt receptacle (20) as noted during removal 10 Circuit a. Bracket (14) Position On two mounting studs breakers b. Two locknuts Install and Secures bracket (14) (12) (13) tighten c. Six circuit Install Snap into bracket (14) breakers (12) d. Lights wiring Connect To same side of circuit harness elec- breakers (12) as tagged trical leads 2-314 | 