TM 9-2320-285-24-1
2-30. 24V INVERTER MAINTENANCE (CONT)
STEP
LOCATION
ITEM
ACTION
REMARKS
INSTALLATION (cont)
9
g. 12-volt recep-
Position
In rear hood enclosure; align
(cont)
tacle (20)
receptacle mounting holes
with cover hinge at the top
h. Two capscrews
Install and
(19), lock
tighten
washers (18),
and nuts (17)
i. Boot (16)
Install
Push onto 7-wire cable (29),
small diameter end first
j. 7-wire cable
Connect
To 12-volt receptacle (20) as
(29) leads
tagged
k. Seven screws
Install and
(15)
tighten
l. Boot (16)
Slide
Onto 12-volt receptacle (20)
forward
m. Electrical tape
Install
Wrap new electrical tape
around 7-wire cable (29)
and 12-volt receptacle (20)
as noted during removal
10
Circuit
a. Bracket (14)
Position
On two mounting studs
breakers
b. Two locknuts
Install and
Secures bracket (14)
(12)
(13)
tighten
c. Six circuit
Install
Snap into bracket (14)
breakers (12)
d. Lights wiring
Connect
To same side of circuit
harness elec-
breakers (12) as tagged
trical leads
2-314
|