TM 9-2320-285-24-1
2-30. 24V INVERTER MAINTENANCE (CONT)
STEP
LOCATION
ITEM
ACTION
REMARKS
INSPECTION/REPAIR
7
a. Circuit
Inspect
Replace if cracked or other-
breakers (12)
wise defective
b. Boot (16) and
Inspect
Replace if cut, cracked, or
cover (34)
deteriorated
c. 12-volt recep-
Inspect
Replace if cracked, pins bent
tacle (20)
or missing, hinge broken,
or threads damaged
d. Electrical
Inspect
Replace if jacket or insul-
wires (31)
ation cracked, cut, or
and 7-wire
frayed, or if conductors
cable (32)
corroded or broken. Replace
defective terminals (35) as
follows:
a. Cut wire as close to
terminal as possible
b. Strip 1/4-inch insula-
tion from wire end
c. Install new terminal;
use crimping tool in
electrical connector
tool kit
e. 7-wire cable
Inspect
Replace if jacket or insul-
(29)
ation cracked, cut, or
frayed, or if conductors or
terminals corroded or
broken
f. Electrical
Inspect
Replace 24-volt receptacle
wires (28)
(27) with wires as an as-
sembly if insulation cut,
cracked, or frayed, or if
conductors corroded or
broken
g. 24-volt recep-
Inspect
Replace if shell cracked or
tacle (27)
deformed, or if hinge
broken. Replace bent, cor-
roded, or broken contacts
using parts and tools in
electrical connector tool
kit
h. Inverter (7)
Inspect
Replace if fuse holders,
housing, or terminal strips
cracked or broken or in-
verter otherwise defective
i. Plastic tubing
Inspect
Replace if cracked, chafed,
(23 and 30)
or deteriorated
2-312
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |