TM 9-2320-285-24-1
2-29. WATER LEVEL WARNING KIT MAINTENANCE (CONT)
STEP
LOCATION
ITEM
ACTION
REMARKS
INSPECTION
19
a. Clamps (3, 4,
Inspect for:
Replace if defects observed
17, 18, and
wear
19)
damage
b. Hoses (5 and 6)
Inspect for:
Replace if defects observed
cracks
deteriora-
tion
c. Two tees (20)
Inspect for:
Replace if defects observed
cracks
damage
d. Remaining parts
Inspect for:
Replace as necessary
cracks
wear
damaged
threads
INSTALLATION
NOTE
When reinstalling parts use pipe thread compound on all fitting/elbow threads to prevent leakage.
20
Frame rail,
a. Four clamps
Position
On end of hoses routed to
left side
(19)
heater, thermostat housing
and water pump
b. Two tees (20)
Install
In hose ends
c. Clamps (17 and
Install
On end of hoses (5 and 6)
18)
d. Hoses (5 and 6)
Install
On end of tees (20)
e. Clamps (17 and
Position and
On end of hoses (5 and 6)
18)
tighten
f. Two clamps (16)
Position
On hoses (5 and 6)
g. Two lock wash-
Install and
ers (15) and
tighten
capscrews (14)
21
Water level
a. Bracket (9)
Install
Screw clockwise into water
sensor (10)
level sensor (10)
b. Connector (13)
Install
In water level sensor (10)
c. Elbow (12)
Install
On bracket (9) pipe nipple
d. Connector (11)
Install
In elbow (12)
2-304
|