TM 9-2320-285-24-1
2-29. WATER LEVEL WARNING KIT MAINTENANCE (CONT)
STEP
LOCATION
ITEM
ACTION
REMARKS
INSTALLATION (cont)
22
Transmis-
a. Water level
Position
sion mount
sensor (10)
and bracket
(9)
b. Two capscrews
Install
Secures bracket (9)
(7) and nuts
(8)
c. Hoses (5 and 6)
Connect
To connectors (11 and 13)
d. Clamps (3 and 4)
Position and
tighten
23
Water level
a. Red and green
Strip 1/4 inch insulation from ends
sensor (10)
wires
b. Engine harness
Strip 1/4 inch insulation from ends
wire leads
(white and
blue/brown)
c. Crimp connectors
Install and
Route wire leads into crimp
(1 and 2)
crimp
connector as tagged in
securely
step 15 above
24
Radiator
Fill neck
Fill with
coolant
2-305
|