TM 9-2320-285-24-1
2-29. WATER LEVEL WARNING KIT MAINTENANCE (CONT)
STEP
LOCATION
ITEM
ACTION
REMARKS
REMOVAL (cont)
16
Bracket (9)
a.
Connector (11)
Remove
From elbow (12)
and water
b.
Elbow (12)
Remove
From bracket (9)
level
c.
Connector (13)
Remove
From water level sensor (10)
sensor (10)
d.
Bracket (9)
Remove
From water level sensor (10)
by unscrewing it
NOTE
Perform the following steps only if hoses (5 and 6) and/or tees (20) require replacement.
17
Frame rail,
a. Two capscrews
Remove
left side
(14) and lock
washers (15)
b. Two clamps (16)
Remove
c. Clamps (3 and
Remove
4)
d. Clamps (17 and
Loosen
18)
e. Hoses (5 and 6)
Remove
Remove clamps (17 and 18)
from hoses
f. Four clamps (19) Loosen
g. Two tees (20)
Remove
CLEANING
18
a. Hoses (5 and 6)
Clean
Use clean cloth moistened
with mild detergent; dry
using clean cloths
WARNING
Dry cleaning solvent (P-D-680), used to clean parts is toxic and flammable. Wear protective goggles and
gloves and use only in a well ventilated area. Avoid contact with skin, eyes, and clothes and don't breathe
vapors. Do not use near open flame or excessive heat and don't smoke when using it. Failure to do so
could cause serious injury. If you become dizzy while using cleaning solvent, get fresh air and medical
attention immediately. If contact with skin or clothes is made, flush with large amounts of water. If contact
with eyes is made, wash eyes with water and seek medical aid immediately.
b. Remaining parts
Clean
Use cleaning solvent P-D-680;
dry using clean cloths
2-303
|