WINDSHIELD WASHER CONTROL VALVE - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
1.
Air system
Drain (TM 9-2320-270-10).
2. Elbow (1)
Airline(2)
Using 9/16-inch wrench, unscrew and pull
out.
3. Air line (2)
Insert (3)
Using long-nose pliers, pull out.
or elbow (1)
4. Hose (4) to
Clamp (6)
Using pliers, open and slide back.
adapter (5)
5. Adapter(5)
Hose (4)
Pull off.
6. Valve (7) to
Two screws (9),
a. With help from assistant and using
firewall (8)
washers (10),
7/16-inch box wrench, 7/16-inch
nuts (11), and
socket, extension, and handle, unscrew
Iockwashers (12)
and take off.
b. Get ridofIockwashers(11).
7. Firewall (8)
Valve (7)
Take out.
TA240736
4-1183

Privacy Statement - Press Release - Copyright Information. - Contact Us