WINDSHIELD WASHER CONTROL VALVE - CONTINUED
ACTION
REMARKS
ITEM
LOCATION
DISASSEMBLY
a. Secure valve (1) in vise.
Elbow (2)
8. Valve (1)
b. Using 7/16-inch open-end wrench,
unscrew and take out.
a. Using 7/16-inch box wrench, unscrew
Adapter (3)
9.
and take out.
b. Remove valve (1) from vise.
CLEANING
Clean according to general maintenance
All parts
10.
instructions (page 4-l).
lNSPECTION/REPLACEMENT
Inspect according to general maintenance
All parts
11.
instructions (page 4-1).
ASSEMBLY
a.
Secure valve (1) in vise.
Adapter (3)
12. Valve (1)
Wrap threads with teflon tape
b.
(page 4-1)
c.
Screw in and tighten using 7/16-inch
box wrench.
a.
Wrap threads with teflon tape
Elbow (2)
13.
(page 4-1).
Screw in and tighten using 7/16-inch
b.
open-end wrench.
c.
Remove valve (1) from vise.
INSTALLATION
Place in position.
Valve (1)
14. Firewall (4)
With help from assistant, screw in and
Two screws (5),
15. Valve (1) to
tighten using 7/16-inch box wrench,
washers (6), new
firewall (4)
7/16-inch socket, extension, and handle.
Iockwashers (7),
and nuts (8)
Lube end lightly with soap and push on.
Hose (9)
16. Adapter (3)
Using pliers, open and slide down over
Clamp (10)
17. Hose (9) to
adapter (3).
adapter (3)