TM9-2320-270-20-2
PRIMARY AIR RESERVOIR CHECK VALVE - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
9. Check valve (4)
Elbow (1)
a. Wrap threads with teflon tape
(page 4-1).
b. Screw in and tighten using 1 1/16-inch
wrench.
10. Elbow (1)
Insert (3)
Push in and using plastic hammer, seat.
11.
a. Lube end with soap and push in
Air line (2)
until seated.
b. Screw on and tighten using 1 1/8-inch
wrench.
NOTE
FOLLOW-ON MAINTENANCE: Check for leaks (page 4-1).