TM 9-2320-270-20-1
DIRECTIONAL SIGNAL FLASHER - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
4. Flasher holder (8)
Flasher (1)
Pull out.
INSTALLATION
5. Flasher holder (8)
Flasher (1)
Push in.
Flasher does not go all the way to
bottom of holder.
6. Terminal L (6)
Black wire (7)
Plug in.
7. Terminal P (4)
Gray wire (5)
Plug in.
8. Terminal X (2)
Wire 080 (3)
Plug in.
NOTE
FOLLOW-ON MAINTENANCE:
1. Connect battery ground cable (page 4-444).
2. Check operation (TM 9-2320-270-10).
3. Close instrument panel (page 4-244).
TASK ENDS HERE
TA240012
4-319
|