TM 9-2320-270-20-1
DOME LIGHT SWITCH AND WARNING LIGHT SWITCH - CONTINUED
NOTE
FOLLOW-ON MAINTENANCE:
1. Connect battery ground cable (page 4-444).
2. Check operation (TM 9-2320-270-10).
3. Close instrument panel (page 4-244).
TASK ENDS HERE
WORK LIGHT SWITCH
This task covers:
a. Removal (page 4-296)
b. Installation (page 4-297)
INITIAL SETUP
Personnel Required
Tools
One
Screwdriver, flat-tip, 1/4-inch
Wrench, box, 9/16-inch
Equipment Condition
Materials/Parts
Battery ground cable disconnected
(4-444).
Lockwasher, terminal screw
Instrument panel open (page 4-244).
(two required)
Tag, marking (item 18, appendix C)
ACTION
ITEM
REMARKS
LOCATION
REMOVAL
WARNING
Make sure battery ground cable is disconnected before doing this task. Failure to dis-
connect battery ground cable can cause personal injury and damage to electrical
system.
NOTE
Tag wires according to general maintenance instructions (page 4-1).
1. Terminal (1)
Screw (2), lock-
s. Using screwdriver, unscrew and take
off.
washer (3), and
wire 040A (4)
b. Get rid of Iockwasher (3).
4-296

Privacy Statement - Press Release - Copyright Information. - Contact Us