TM 9-2320-270-20-1
DOOR AJAR WARNING RELAY
This task covers:
a. Removal (page 4-242)
b. Installation (page 4-243)
INITIAL SETUP
Tools
Personnel Required
Screwdriver, cross-tip, number 3
One
Screwdriver, flat-tip, 1/4-inch
Equipment Condition
Materials/Parts
Battery ground cable disconnected
Lockwasher, relay to firewall
(two required)
Tag, marking (item 18, appendix C)
ACTION
ITEM
LOCATION
REMARKS
REMOVAL
WARNING
Make sure battery ground cable is disconnected before doing this task. Failure to
disconnect ground cable can cause personal injury and damage to electrical system.
NOTE
Tag wires according to generaI maintenance instructions (page 4-1).
1. Horn relay (1) and
Screw (3)
Using flat-tip screwdriver, unscrew part
terminal (2)
way.
2.
Wire 429 (4)
Pull out.
3. Terminal (5)
Screw (6)
Using flat-tip screwdriver, unscrew part
way.
4.
Wire 376 (7)
Pull out.
5. Terminal (8)
Screw (9)
Using flat-tip screwdriver, unscrew part
way.
6.
Wire 331 (10)
Pull out.
4-242