TM9-2320-270-20-1
TROUBLESHOOTING - CONTINUED
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
74. NEITHER WINCH OPERATES CONTINUED.
Open left side of hood and remove left side panel (TM 9-2320-270-10). Go to
Step 12.
chassis firewall connector (1). Using multimeter set at 30 vdc, put red probe on
terminal N (2) and black probe to good ground.
If meter reads no voltage, put key in OFF position, install left side panel
and close left side of hood (TM 9-2320-270-10) and notify direct
support maintenance.
Install left side panel and close left side of hood (TM 9-2320-270-10) and open
Step 13.
instrument panel (page 4-244). Go to air solenoid valve (3). Using multimeter
set at 30 vdc, put red probe on terminal for wire no. 170 (4) and black probe to
good ground.
If meter reads no voltage, put key in OFF position, close instrument
panel (page 4-244) and notify direct support maintenance.