TROUBLESHOOTING - CONTINUED
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
74. NEITHER WINCH OPERATES CONTINUED.
Open instrument panel (page 4-244). Go to instrument panel circuit breaker
Step 4.
(l). Using multimeter set at 30 vdc, put red probe on terminal (2) for wire no.
075 and black probe to good ground.
If meter reads voltage, put key in OFF position and replace circuit
a.
breaker (page 4-304).
b. If meter does not read voltage, put key in OFF position, close instru-
ment panel (page 4-244).
Go to terminal for wire no. 437 on neutral safety switch (3) on shift tower (4).
Step 5.
Using multimeter set at 30 vdc, put red probe on terminal and black probe to good
ground.
If meter reads no voltage, put key in OFF position and notify direct
support maintenance.