TM9-2320-270-20-1
TROUBLESHOOTING - CONTINUED
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
WINCH SYSTEM
74. NEITHER WINCH OPERATES.
Step 1.
Start engine and build air pressure to operating level (TM 9-2320-270-10).
Engage winch station (TM 9-2320-270-10). Open driver's door of cab (l).
If electric horn does not blow, go to step 10.
Step 2.
Check OIL PRESS gage (2), WATER TEMP gage (3), and BATTERY (4).
If three gages are working, shut down engine (TM 9-2320-270-10) and
go to step 5.
Step 3.
Check instrument panel circuit breaker (5) shut down engine
(TM 9-2320-270-10) and put key in accessory position. -
If breaker is tripped, push button in to reset breaker.
3-187
|