TM 9-2320-270-20-1
TROUBLESHOOTING - CONTINUED
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
40. TRANSMISSION OIL TEMPERATURE GAGE DOES NOT INDICATE CORRECT TEMPERATURE
(CONTINUED).
Open instrument panel (page 4-244). At wire no. 405 (1) terminal, using
Step 3.
using multimeter set on 30 vdc, put red probe on terminal (1) and black
probe to good ground.
If meter reads zero, put ignition switch in OFF position, close instrument
panel (page 4-244) and notify direct support maintenance.
At oil temperature gage (2), using multimeter set at 30 vdc, put red probe on
Step 4.
terminal for wire no. 422 (3) and black probe to good ground.
If meter reads zero, put ignition switch in OFF position and replace gage
TA239697
3-110