MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
29. WARNING LIGHT DOES NOT WORK CONTINUED,
Step 3.
At dome light circuit breaker (1), using multimeter set at 30 vdc, put red
probe on wire no. 029 (2), and black probe to good ground.
If meter reads no voltage, put headlight switch in OFF position and
replace circuit breaker (page 4-304).
At warning switch (3), using multimeter set at 30 vdc, put red probe on wire
Step 4.
no. 029 (2), from breaker to switch and black probe to good ground.
If meter reads no voltage, put headlight switch in OFF position, close
instrument panel (page 4-244), and notify direct support maintenance.
Put warning switch (3) in ON position. Using multimeter set at 30 vdc,
Step 5.
put red probe on wire no. 029 (2) from switch to warning, and black probe to
good ground.
a. If meter reads no voltage, put headlight switch and warning switch
(3) in OFF position and replace warning switch (page 4-294).
b. If meter reads voltage, put headlight switch and warning switch in
OFF position and close instrument panel (page 4-244).