MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
23. SIDE MARKER LIGHT DOES NOT WORK - CONTINUED.
Step 4.
Using multimeter set at 30 vdc, put red probe on circuit breaker terminal (1) and
black probe on panel (2).
If meter reads no voltage, go to step 6.
Step 5.
Using multimeter set at 30 vdc, put red probe on clearance light switch terminal
(3) and black probe on panel (2).
a. If meter reads no voltage, close instrument panel (page 4-244) and
notify direct support maintenance.
b. If meter reads voltage, replace clearance light switch
Step 6.
Using multimeter set at 30 vdc, put red probe on circuit breaker terminal (1)
and black probe on panel (2).
a. If meter reads no voltage, close instrument panel (page 4-244), put
clearance light switch in OFF position, and notify direct support
maintenance.
b. If meter reads voltage, put clearance light switch in OFF position and
replace CL LPS circuit breaker (page 4-304).