TM 9-2320-270-20-1
TROUBLESHOOTING - CONTINUED
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Step 5.
Using
set at 30
put red probe on circuit breaker terminal (6) and
black probe on panel (4).
If meter reads no voltage, close instrument panel (page 4-244) and
notify direct support maintenance.
Using multimeter set at 30 vdc, put red probe on circuit breaker terminal (7) and
Step 6.
black probe on panel (4).
a. If meter reads no voltage, replace TURN SIG circuit breaker
b. If meter reads voltage, close instrument panel (page 4-244) and
notify direct support maintenance.
Step 7.
Put clearance light switch in OFF position. Put headlight switch (8) in ON
position.
a. If headlights work, put headlight switch in OFF position, close instru-
ment panel (page 4-244) and notify direct support maintenance.
b. If headlights do not work, do steps 6 thru 9 under BOTH HEADLIGHTS
DO NOT WORK (page 3-48).
TA239645
3-57
|