TM 9-2320-270-20-1
TROUBLESHOOTING - CONTINUED
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
19. FRONT DIRECTIONAL LIGHT DOES NOT WORK - CONTINUED.
Install directional light lamp (page 4-320). Put clearance light switch (1) in
Step 2.
ON position, and make sure blackout switch (2) is in LIGHTS position.
If marker lights do not work, go to step 7.
Put clearance light switch (1) in OFF position. Open instrument panel
Step 3.
terminal X (3) and black probe on panel (4).
If meter reads no voltage, go to step 5.
Step 4.
Using multimeter set at 30 vdc, put red probe on flasher terminal L(5) and black
probe on panel (4).
If meter reads no voltage, replace flasher (page 4-318).
TA239644