TM9-2320-270-20-1
TROUBLESHOOTING - CONTINUED
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
12. ENGINE WATER TEMPERATURE GAGE SHOWS lNCORRECT TEMPERATURE DURlNG OPERATlON
(MORE THAN 185F (85C) OR LESS THAN 160F (71C)) - CONTINUED.
Using multimeter set at 30 vdc, put red probe on oil pressure gage terminal (1)
Step 6.
and black probe on panel (2).
If meter reads no voltage, put key in OFF position, close instrument
panel (page 4-244), and notify direct support maintenance.
Using multimeter set at 30 vdc, put red probe on water temperature gage terminal
Step 7.
(3) and black probe on panel (2).
a. If meter reads no voltage, put key in OFF position, close instrument
panel (page 4-244), and notify direct support maintenance.
b. If meter reads voltage, put key in OFF position, and replace water
temperature gage (page 4-262).
c. If engine water temperature gage still shows incorrect temperature,
close instrument panel (page 4-244) and notify direct support
maintenance.
3-40
|