TM 9-2320-270-20-1
WATER TEMPERATURE GAGE
This task covers:
a. Removal (page 4-262)
b. Installation (page 4-264)
INITIAL SETUP
Materials/Parts Continued
Tools
Lockwasher, wire to terminal
Wrench, open-end, 3/8-inch
Lockwasher, terminal to voltage adapter
Tag, marking (item 18, appendix C)
Materials/Parts
Personnel Required
Lockwasher, wires to voltage adapter
lGN terminal
One
Lockwasher, voltage adapter gage
Equipment Condition
Instrument panel open (page 4-244).
ACTION
REMARKS
ITEM
LOCATION
REMOVAL
CAUTION
Ignition switch must be off before replacing water temperature gage to prevent possible
damage to electrical system.
NOTE
Tag wires according to general maintenance instructions (page 4-1).
Pull out.
Instrument panel
1.
Water temperature
lamp assembly (2)
gage (1)
Using wrench, unscrew and take off.
Nut (4)
2.
IGN terminal (3)
a. Take off.
Lockwasher (5),
3.
b. Get rid of Iockwasher (5).
oil-water warning
lamp wire (6), and
black wire 320 (7)
Using wrench, unscrew and take off.
Nut (9)
4. Sending unit
terminal (8)
4-262
|