Click here to make tpub.com your Home Page

Page Title: PREVENTIVE MAINTENANCE CHECKS AND SERVICES - CONTINUED
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM9-2320-270-20-1
PREVENTIVE MAINTENANCE CHECKS AND SERVICES - CONTINUED
A ANNUALLY
S SEMIANNUALLY
ITEM
INTERVAL
TO BE
ITEM
s
PROCEDURE
INSPECTED
A
NO.
58
WARNING
Do not touch positive Iead on back of alternator
with anything metal unless batteries are dis-
connected. You could damage alternator or
cause personal injury.
a. Inspect alternator mounting brackets for
damage and security. Tighten loose mounting
bracket bolts. Replace damaged bracket (page
b. Inspect wiring for security and damage.
Tighten loose wires, repair damaged wiring.
c. Adjust alternator belts (page 4-223).
a. Inspect radiator, shroud, and hoses for
59
Radiator,
leaks and damages. Replace leaking or damaged
Shroud and
parts (pages, 4-143,4-151, and 4-160).
Hoses
b. Inspect radiator cap for damage. Replace
damaged radiator cap (page 4-143).
c. Check coolant level, condition, and anti-
freeze protection. Add or change coolant if needed
(TM 9-2320-270-10).
Remove rocker arm and valve cover (pages 4-12 and
Injector Pipes
60
4-18). Start engine (TM 9-2320-270-10). Inspect
injector pipes for leaks and damage. If injector
pipes are leaking or damaged, notify Direct
Support Maintenance. Shut down engine (TM 9-
2320-270-10), install rocker arm and valve covers
a. Inspect oil breather valves and hoses for
Breather Valves
61
damage. Replace damaged parts (pages 4-12 and
and Hoses
b. Service breather (LO 9-2320-270-12).
2-20

Privacy Statement - Press Release - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business