TM 9-2320-269-34-1
ANTILOCK CONTROL MODULES - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
REMOVAL - CONTINUED
5.
Module control (1)
Ground wire clip (7)
Take off.
6
Fuse (8)
If defective, using 1/4-inch flat-tip
screwdriver, pry up and take out.
7
Three screws (9),
a. Using 1/2-inch socket, ratchet handle
lockwashers (10),
with 3/8-inch drive, and 1/2-inch
and nuts (11)
open-end wrench, unscrew and take
off.
b. Get rid of lockwashers (10).
8.
Frame (12)
Module control (1)
Take off.
INSPECTION/REPLACEMENT
NOTE
For more information on how to inspect parts, go to General Maintenance Instructions (page 2-46).
The modules are solid state and completely sealed, and if damaged or defective, they must be replaced.
TA238252
2-499
|