TM 9-2320-269-34-1
ETHER SUPPLY LINES - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
REMOVAL - CONTINUED
5. Fitting (2)
Two tubes (5)
Using 318-inch and 7/16-inch open-end
wrenches, unscrew and take off.
6. Two intake
Two intake manifold
Using 7/16-inch open-end wrench,
manifolds (9)
connectors (4)
unscrew and take out.
CLEANING
NOTE
For more information on how to clean parts, go to General Maintenance Instructions (page 2-46).
Solvent burns easily. Solvent fumes can explode. Do not smoke or allow open flame nearby when
using solvent. Failure to observe these precautions could cause serious injury or death.
7.
Fitting (2) and
a. Clean in drycleaning solvent.
two intake manifold
b. Wipe dry with clean rags.
connectors (4)
8.
Three tubes
Using clean rags, wipe clean.
(3) and (5)
(1)
TA238165
2-385
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |