Click here to make tpub.com your Home Page

Page Title: ASSEMBLY - CONTINUED
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 9-2320-269-34-1
FUEL INJECTORS - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
ASSEMBLY - CONTINUED
28.
Injector (10)
a
Repeat steps 12 and 13.
b.
If opening pressure is not 2800 +
50 psi (19306 + 344 kPa),
repeat steps 14 thru 17 and add or
remove adjusting shims to raise or
lower opening pressure as needed.
c.
If spray pattern is irregular, repea t
steps 14 thru 24.
d.
If adjustment or cleaning was needed,
repeat steps 25 thru 29.
INSTALLATION
WARNING
Solvent burns easily. Solvent fumes can explode. Do not smoke or allow open flame nearby when
using solvent. Failure to follow these precautions could result in serious Injury or death.
CAUTION
The Injector must seat flush for proper operation. Do not clean mating surfaces with tools.
29.
Cylinder head (11)
Injector bore (12)
a  Take off rag.
and mating
b  Wipe clean with clean ra gs dampened
surface (13)
with drycleaning solvent.
2-255

Privacy Statement - Press Release - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business