INTAKE AND EXHAUST VALVES - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
REMOVAL - CONTINUED
1.
Valve (1) and
Two valve spring
a.
Place cylinder head (2) in
vertical
cylinder head (2)
retainers (3)
position.
b.
Using valve spring compressor, take
off retainers (3).
It may be necessary to tap end of
valve with soft plastic-face
hammer
to loosen retainers.
2.
Valve stem seal
a.
Release spring compressor.
(4), valve spring
b.
Take out parts.
cup (5), valve
c.
Get rid of stem seal (4) and spring
spring and damper
and damper assembly (6).
assembly (6), and
valve rotator cup
assembly (7)
3.
Cylinder head (2)
Valve (1)
Take out.
TA238006