TM 9-2320-269-34-1
TROUBLESHOOTING - CONTINUED
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
18. LOW AIR PRESSURE OR AIR PRESSURE LOSS
Check power divider lockout assembly (6) for leaking.
a. Coat power divider lockout assembly (6) with soapy water.
b. Start engine, let air pressure build up, and shut off
(TM 9-2320-269-10).
c. Check power divider lockout assembly (6) for soap bubbles.
d. Have assistant turn power divider lockout control valve (7) to the IN
position, and check power divider lockout assembly (6) for soap
bubbles.
e. Have assistant turn power divider lockout control valve (7) to the OUT
position.
f. If power divider lockout assembly (6) leaks, repair or replace as
needed (page 2-1012).
TA237917
2-25
|