TM 9-1290-335-34&P
4-8. KNOB (RESETTER) INSTALLATION
TOOLS:
3/16" flat tip screwdriver
PERSONNEL: One
EQUIPMENT: CONDITION: Azimuth indicator on work bench
Caution
Knob assembly will be spring loaded. Use caution in its assembly.
FRAME 1
Step
Procedure
1.
Place gasket (1) in cup (2) and line up holes.
2.
Place gasket (1) and cup (2) on housing (3) and line up holes.
3.
Place retainer (4) and spring (5) on knob (6).
4.
Carefully press spring (5), retainer (4), and knob (6) on gasket (1) and cup (2) and line up holes.
5.
Using screwdriver, install four screws (7) in knob (6).
NOTE
FOLLOW-ON MAINTENANCE
Do checkout procedure (Vol I, para 2-2).
END OF TASK
Vol II
Para 4-8
4-6
|