TM 9-1290-335-34&P
Section 3. KNOB (RESETTER)
4-6. KNOB (RESETTER) MAINTENANCE PROCEDURES INDEX
Task
Reference (para)
Removal
4-7
Installation
4-8
4-7. KNOB (RESETTER) REMOVAL
TOOLS:
3/16' flat tip screwdriver
PERSONNEL: One
EQUIPMENT CONDITION: Azimuth indicator on work bench
CAUTION
Knob assembly is spring loaded. Be careful during removal.
FRAME 1
Step
Procedure
1.
Press knob (1) in and hold.
2.
Using screwdriver, remove four screws (2).
3.
Slowly remove knob (1).
4.
Remove retainer (3) and compression spring (4).
5.
Remove gasket (5) and cup (6) from azimuth indicator.
END OF -TASK
Vol II
Para 4-6
4-5
|