4-5. SCALE DIAL (GUNNER'S AID) INSTALLATION
TOOLS:
#2 cross tip screwdriver (Phillips type)
3/32" socket head screw key (Allen wrench or equivalent)
PERSONNEL: One
EQUIPMENT CONDITION: Azimuth indicator on work bench
WARNING
Be careful when assembling to avoid personal injury with spring.
FRAME 1
Step
Procedure
1.
Install clamp (I) over housing assembly (2) and line up setscrew holes with slots in window.
2.
Using Allen wrench, install six setscrews (3).
3.
Place spring tension clip (4) in groove in-clamp (1) with bent ends in.
4.
Holding spring tension clip (4) on clamp (1), slip dial (5) over spring tension clip (4) and clamp (1).
5.
Using screwdriver, install three screws (6) to hold dial (5).
NOTE
FOLLOW-ON MAINTENANCE
Do checkout procedure (Vol I, para 2-2).
END OF TASK