4-3. SCALE DIAL (GUNNER'S AID) MAINTENANCE PROCEDURES INDEX
Task
Reference (para)
Removal
4-4
Installation
4-5
4-4. SCALE DIAL (GUNNER'S AID) REMOVAL
TOOLS:
#2 cross tip screwdriver (Phillips type)
3/32" socket head screw key (Allen wrench or equivalent)
PERSONNEL: One
EQUIPMENT CONDITION: Azimuth indicator on work bench
WARNING
Dial (Gunner's Aid) Assembly is spring loaded. Be careful
and lift off slowly when removing.
FRAME 1
Step
Procedure
1.
Using screwdriver, remove three screws (1) from dial (2).
2.
Slowly lift off dial (2); spring tension clip (3) will be released.
3.
Using Allen wrench, remove six setscrews (4) and remove clamp (5).
END OF TASK
Vol II