FIRE CONTROL LEVEL ASSEMBLY
TOOLS: 0.055 to 0.060 adjustable face spanner wrench
4 oz. ballpeen hammer
1/16" drive pin punch
0.055 jeweler's screwdriver
1/4" flat tip screwdriver
PERSONNEL: One
EQUIPMENT CONDITION: Fire control level on work bench
Step
Procedure
NOTE
Do step 1 only if pin (1) was removed.
1.
Using hammer and punch, install pin (1) in housing (2).
2.
Position cover (3) on housing (2) and hold in place while installing level vial tube (4).
Make sure level vial tube (4) is lined up with pin (1)  in housing (2).
3.
Place eccentric (5) into threaded ring (6).
4.
Using spanner wrench, install threaded ring (6) with eccentric (5). Do not tighten.
5.
Install and adjust fire control level (para 4-16).
END OF TASK