TM 9-1220-220-34
2-2.
PERFORMANCE TEST (CONT)
FRAME 8
Step
Procedure
Symptom
Maintenance Action
NOTE
Do steps 1 thru 3 for M10,
M10A1, and M10A6 config-
urations only.
1.
Remove electrical connector
(1) from housing (2).
2.
Using multimeter, check that
Faulty light assembly.
a. Replace lamp (TM 20-2)
resistance between housing
(2) and plug (3) is 6+.5
b. Disassemble light as-
ohms.
sembly and check for
worn, corroded, or
broken parts and re-
place (Vol II, para
3.
Install connector (1) in
light assembly housing (2).
NOTE
FOLLOW-ON MAINTENANCE
Correct remaining faults
listed on DA Form 2404.
Do final inspection (Vol II,
END OF TASK
2-16
|