Table 2-1. Troubleshooting - Continued
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
(4). Unscrew BIAS control locking knob from BIAS control shaft and remove.
(5). Remove five screws (fig. 2-22) securing edge-lighted panel to control panel.
TS 006262
(6). Using orangewood sticks, lift edge-lighted panel (fig. 2-22) off control panel.
(7). Unsolder the electrical leads (fig. 2-23) from the defective switch or control and tag for iden-
tification.
(8). Remove the attaching parts securing the switch or control to the panel assembly and remove
switch.
(9), Install new switch or control in panel assembly and secure with attaching parts. Connect and
solder electrical leads to switch in accordance with the identification tags on the electrical leads.