Figure 4-10. Reading DC Voltage (TS-352B/U).
Thus the meter (fig. 4-11) is showing the following readings:
Switch Setting
Reading
100 DC VOLTS
20 VOLTS DC
10 DC VOLTS
2 VOLTS DC
1 DC VOLT
.2 VOLTS DC
d. Using the AC Volts Scale. The ac volts scale is used to measure the 115 ac voltage found in the control panel.
(1) Before using the multimeter to measure 115 ac or 220 ac voltage, do the following steps that match the
multimeter you have.
(a) AN/URM-105. Set meter switch to "1000 AC Volts" (fig. 4-12).
(b) TS-352B/U.
1. Set "FUNCTION" switch to "AC Volts" ("Range" switch can be at any setting) (A, fig. 4-13).
2. Put black lead in "-DC/+AC/OHMS" jack (B, fig. 4-12).
3. Put red lead in "250V" jack on right side of meter.