TM 5-6640-214-14
Figure 4-9. Reading DC Voltage (Simpson 160).
2. TS-352B/U. Read the "dc" volts scale for the range the red lead is plugged in at.
3. AN/URM-105. Read the upper, black, straight-lined portion of the "ac and dc volts" scale for the
range the selector switch is set at.
Range
Scale
50V
0-5 (and multiply by 10)
10V
0-10
2.5V
0-2.5
Thus the meter (fig. 4-10) is showing the following reading:
Switch
Setting
Scale
1000 DC Volts
0-10 (and multiply by 100)
100 DC Volts
0-10 (and multiply by 1-10)
10 DC Volts
0-10
1 DC Volt
0-10 (and divide by 10)
4-14
|