Click here to make tpub.com your Home Page

Page Title: Figure 4-9. Reading DC Voltage (Simpson 160).
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 5-6640-214-14
Figure 4-9. Reading DC Voltage (Simpson 160).
2. TS-352B/U. Read the "dc" volts scale for the range the red lead is plugged in at.
3. AN/URM-105. Read the upper, black, straight-lined portion of the "ac and dc volts" scale for the
range the selector switch is set at.
Range
Scale
50V
0-5 (and multiply by 10)
10V
0-10
2.5V
0-2.5
Thus the meter (fig. 4-10) is showing the following reading:
Switch
Setting
Scale
1000 DC Volts
0-10 (and multiply by 100)
100 DC Volts
0-10 (and multiply by 1-10)
10 DC Volts
0-10
1 DC Volt
0-10 (and divide by 10)
4-14