TM 5-6640-213-14
Table 4-2. Ice Maker Troubleshooting -Continued
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
12. WATER IS RUNNING FROM MOLD INTO MECHANISM HOUSING BEHIND
WHITE COVER AND THE MICROSWITCHES ARE BECOMING CORRODED
AND INOPERATIVE.
Ice maker is not level.
Level ice maker and replace inoperative microswitches.
13. ICE MAKER MOLD IS NOT LEVEL.
Mold mounting has vibrated loose.
Place level on mold. Adjust and retighten mold mounting.
14. CUBES STICKING TOGETHER.
Step 1.
Check for poor door seal.
Adjust or replace seal.
Step 2.
Check if temperature control improperly adjusted.
Adjust temperature control (para. 4-5e.).
Step 3.
Check if ice maker is not level.
Level ice maker.
Step 4.
Check for poor air circulation.
Remove obstruction from grille.
Step 5.
Check if ice has fused together on standing.
Ruffle or disturb ice daily.
4-13
|