TM 5-6640-213-14
Table 4-2. Ice Maker Troubleshooting - Continued
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
8. ICE MAKER FAILS TO MAKE ENOUGH ICE.
Step 1. Temperature control is set too cold.
Turn temperature control to the left.
Fan motor is not operating.
Step 2.
Check motor, correct malfunction.
The condenser coil behind grille is dirty, causing malfunction.
Step 3.
Clean coil.
9. ICE CUBES ARE CLOUDY.
Air is being trapped as water freezes rapidly.
No remedy required.
10. TOO MUCH WATER COMING INTO FREEZING MOLD.
Step 1.
Water valve switch has malfunctioned.
Test switch by depressing the button on top. Note click or
tension as switch is being depressed. Adjust or replace
switch as required (para. 4-5d.).
Step 2.
Check if water control has failed.
Replace control (para. 4-5c.).
Step 3.
Check if leakage through the solenoid valve has occurred.
Replace solenoid valve.
11. WATER IS FLOWING OVER THE FREEZING MOLD.
Ice maker is not level.
Level ice maker.
4-12
|