TM 5-6350-275-24&P
Logging Printer Setup (Ref. SAIG)
When installing a new printer, or replacing a defective one, the internal printer configuration parameters
must be properly set. (Refer to the SAIG printer manual in Appendix E) These internal parameters must match
the [SYS]<CONVERSADAQ>SPOOLERCONFIG. SYS file on the B39. A typical example of this file is shown
below. If unsure of your site specific parameters contact the System Administrator for a print out of this data
file. This file may only be viewed from the COMMAND LINE using the C C F (Create Configuration File)
command for a S (Serial) device type.
[SYS]<CONVERSADAQ>SPOOLERCONFIG.SYS (Typical)
[Data bits (5, 6, 7, or 8; default = 7)]
8
[Parity (none, even, odd, 0, or 1; default = 0)]
0
[Baud Rate (default = 9600)]
9600
[Stop bits (1 or 2; default = 1)]
1
[Transmit time out (number of seconds; default = wait forever)]
no time out
[New line mapping mode (binary, CR, or CR/LF; default = CR/LF)]
cr/lf
[Line control (none, XON/XOFF, CTS or both; default = XON/XOFF)]
Xon/Xoff
[Tab expansion (default = 8)]
8
[Number of characters per line (default = 132)]
132
[Translation file (default = none)]
[End of transmission character (None, CR, CR/LF, or FF;Def = CR/LF)]
cr/lf
PRINTER SERIAL PARAMETERS (Typical)
Serial I/F
Parity
None
Serial I/F
Serial Data 7/8 Bits
8 Bits
Serial I/F
Protocol
X-ON/X-OFF
Serial I/F
Busy Line
DTR
Serial I/F
Baud Rate
9600 BPS
Serial I/F
DSR Signal
Invalid
Serial I/F
DTR Signal
Ready on Power UP
Serial I/F
Busy Time
200ms
E-56
|