Click here to make tpub.com your Home Page

Page Title: 9600 Baud Modem Setup (Ref. SAIG)
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 5-6350-275-24&P
9600 Baud Modem Setup (Ref. SAIG)
When installing/replacing a 9600 Baud Modem the following parameters must be set. Refer to the SAIG
Appendix E for additional details.
MODEM SETTINGS
The following modem settings are based on using Motorola UDS V. 32E Modem. Supporting Document No. 6
209 5336 01 014, February 1993, -1993 UDS. There are two portions of the Modem set-up parameters. The first set of
instructions are for the MODEM CONFIGURATION. The second set of instructions are for DTE CONFIGURATION.
MODEM CONFIGURATION
1.
DCE = 9600 TRELLIS
2.
PMC MODEM "FORCED ANSWER"
RSM MODEM "NORMAL ORIGINATE"
3.
FAST TRAIN "DISABLED"
4.
AUTO RETRAIN "ENABLED"
5.
INTERNAL CLOCK
6.
LEASED LINE
7.
4 WIRE
8.
TRANSMIT LEVEL = 0 dB
9.
MANUAL DIAL BACKUP
10.
LOOPBACK TIME = OFF
11.
DIAL LINE JACK - RJ11
12.
LINE CURRENT DIS = LONG
13.
LONG SPACE DISC. = ENABLED
14.
V.22 GUARD TONE = DISABLED
End of the Modem Configuration
DTE CONFIGURATION
1.
ASYNC DATA
2.
DTE RATE = 9600
3.
8 BIT CHARACTER SIZE
4.
ODD PARITY
5.
AT COMMAND SET = DISABLED
6.
IGNORE DTR
7.
DSR FORCED = HIGH
8.
DCD FORCED = HIGH
9.
CTS FORCED = HIGH
10.
DTE FALLBACK = DISABLED
11.
OPTIONS RETAINED AT DISC
End of DTE configuration
E-57

Privacy Statement - Press Release - Copyright Information. - Contact Us