9600 Baud Modem Setup (Ref. SAIG)
When installing/replacing a 9600 Baud Modem the following parameters must be set. Refer to the SAIG
Appendix E for additional details.
MODEM SETTINGS
The following modem settings are based on using Motorola UDS V. 32E Modem. Supporting Document No. 6
209 5336 01 014, February 1993, -1993 UDS. There are two portions of the Modem set-up parameters. The first set of
instructions are for the MODEM CONFIGURATION. The second set of instructions are for DTE CONFIGURATION.
MODEM CONFIGURATION
1.
DCE = 9600 TRELLIS
2.
PMC MODEM "FORCED ANSWER"
RSM MODEM "NORMAL ORIGINATE"
3.
FAST TRAIN "DISABLED"
4.
AUTO RETRAIN "ENABLED"
5.
INTERNAL CLOCK
6.
LEASED LINE
7.
4 WIRE
8.
TRANSMIT LEVEL = 0 dB
9.
MANUAL DIAL BACKUP
10.
LOOPBACK TIME = OFF
11.
DIAL LINE JACK - RJ11
12.
LINE CURRENT DIS = LONG
13.
LONG SPACE DISC. = ENABLED
14.
V.22 GUARD TONE = DISABLED
End of the Modem Configuration
DTE CONFIGURATION
1.
ASYNC DATA
2.
DTE RATE = 9600
3.
8 BIT CHARACTER SIZE
4.
ODD PARITY
5.
AT COMMAND SET = DISABLED
6.
IGNORE DTR
7.
DSR FORCED = HIGH
8.
DCD FORCED = HIGH
9.
CTS FORCED = HIGH
10.
DTE FALLBACK = DISABLED
11.
OPTIONS RETAINED AT DISC
End of DTE configuration