3-36. REPLACE RSMA DES MODULE. (Figure 3-37).
This task consists of:
a. Remove
b. Install
INITIAL SETUP:
Tools:
General Safety Instructions:
Screwdriver, Flat tip (Item 6, App B)
Remove all jewelry while working on
Equipment Condition:
equipment.
Input power removed
Materials/Parts:
Wear ESD wriststrap while handling electronic
RSMA DES Top Module
assemblies.
WARNING
Shut off power source before attempting to disconnect, service, or connect wires or cables. Failure to do
so may result in serious injury or death.
a. Removal
(1)
Loosen screw (12) holding RSMA DES module (11) to RSM.
(2)
Lift up on RSMA DES module (11) and remove from RSM (1).
b. Installation
(1)
Enroll the RSMA DES (11) (Ref. Para. 3-133).
(2)
Align RSMA DES module (11) up with RSM (1) and gently press down on module to seat connectors.
(3)
Secure the RSMA DES module (11) to RSM (1) with screw (12).
(4)
Place the RSM (1) power switch (14) to on, wait approximately 1 minute for self test to complete.
(5)
Pull out on the RSMA DES module (11) jumper wire in order for the DAS module to synchronize with PMC
DES module.
3-114
|