CHAPTER 5
DIRECT SUPPORT, GENERAL SUPPORT AND
DEPOT MAINTENANCE INSTRUCTIONS
Section I GENERAL
59. Scope
60. Record and Report Forms
These instructions are published for the use
For record and report forms applicable to
of field and depot maintenance personnel main-
direct and general support and depot mainte-
taining the Sun Electric Model GPT-3D1
nance, refer to TM 38-750.
load bank. They provide information on the
maintenance of the equipment which is beyond
Note. Applicable forma, excluded standard Form 46
the scope of the tools, equipment, personnel
(United States Government Vehicles Operator's Identi-
or supplies normally available to using orga-
fication Card) which is carried by the operator shall
nizations.
be, kept in a canvas bag mounted on the equipment.
Section Il. DESCRIPTION AND DATA
Mounting----------------- Mount fan hub 3/8-inch
61. Description
from end of shaft.
For a complete description of the load bank
Figure 16. Load bank wiring schematic.
Model GPT-3D-1 see paragraph 8.
(Located in back of manual)
62. Tabulated Data
c. Fan Motor.
a. General. This paragraph contains all the
Type_____________________28 volts DC from AC
input power through
overhaul data pertinent to the direct and
transformer-rectifier
general . support  and depot  maintenance
module.
personnel. A wiring schematic (fig. 16) is also
Ratting ------------------- 1/20 HP minimum at
included.
3600 RPM
Duty__________________Continuous
b. Electrical Power Absorber, Classification
Degree enclosure____________Full
and Rating.
Mounting______________Motor mounting bracket
within power absorber
Rating ------------------- 10 kw
Rpm_______________ 3600 rpm minimum
Resistive element ---------- 1/8-inch Nichrome wire,
4000 rpm maximum
wound counterclockwise,
C l a s s i f a c t i o n and
d. Auto-transformer,
number of turns, spacing
Rating.
and length of ribbon is
determined by wiring
Rating____________ 240 volt, 50-1000 cps,
single phase input, 120
assembly. Motor leads,
volts 1% output at
thermal overload
1 km Forced air cooling
(kilixon) and air switch
at 600 Lineal feet/
leads brought out
through clamp to ter-
minute
125 F ambient
minal board.