TM 43-0156
Step
Function
Mech
Insp
3
c. Arc Chutes (2000 KW).
cont
(1)
Wrap the arc chutes with cushioning (8135-00-855-
6969).
(2) Pack three arc chutes into a wooden box (37-3/4 x 21
x 32) (table B-2-4).
(3) Isolate the arc chutes from the sides of the box and
each other by using 21 x 2 x 4 lumber blocks (5510-
00-220-6194).
(4) Seal box.
d. Preservation of Air Compressor.
(1) Engine.
(a) Drain normal lubrication oil.
(b) Fill preservative oil (9150-00-111-0209).
(c) Remove spark plug.
(d) Atomize spray 1-1/2 ounces of preservative oil
(9150-00-111-0209) through spark plug opening
while manually cranking the engine.
(e) Install spark plug.
(f) Prepare a tag (8135-00-292-2345) indicating
"CRANKCASE FILLED TO OPERATING LEVEL WITH
PRESERVATIVE OIL GOOD FOR OPERATION UNTIL FIRST
REQUIRED LUBRICANT CHANGE - DO NOT DRAIN -
CHECK OIL LEVEL - IF LOW, FILL TO OPERATING LEVEL
WITH OIL AS SPECIFIED IN LO 5-6115-550-12."
(g) Attach the tag to the engine.
(2) Compressor.
(a) Drain normal lubrication oil from crankcase.
(b) Fill crankcase with preservative oil (9150-00-
111-0209).
(c) Remove the air cleaner element.
B-2-87
|