TM 43-0156
Step
Function
Mech
Insp
3
(7)
Prepare a tag (8135-00-292-2345) indicating "BARRIER
cont
HAS BEEN PLACED BETWEEN DISK AND MAGNETS OF
RELAYS, REMOVE BEFORE OPERATION."
(8)
Attach tag to the start controls on the control unit.
(9)
Remove retaining bolts from the doors of the control
unit. Wrap with barrier (8135-00-226-3124) and pack
in a fiberboard box (6 x 4 x 4). Seal box with tape
(7510-00-297-6655). Secure box in tool box on the
end of the control unit. Prepare a tag (8135-
00-292-2345) indicating "RETAINING BOLTS ARE IN TOOL
BOX." Secure tag to the door with tape (7510-00-
916-9659). Tape 7510-00-890-9875 may be used as
a substitute.
(10)
Place cushioning (8135-00-855-6969) over relays and
switches and secure with tape (751000-916-9659).
-
Tape 7510-00-890-9875 may be used as a substitute.
(11)
Cover frame where it comes in contact with the
control unit with barrier (8135-00-226-3124).
(12)
Cover front of control unit with frame (fig. B-2-2
and table B-2-2).
(13)
Secure frame to control unit with 3-1/2 in. bolts
(5306-00-282-4281) and washers (5510-00-833-3340).
(14)
Preserve batteries as follows:
(a) Disconnect the battery positive and negative
cables which run to the battery knife switch of
the battery end only.
(b) Coat cable ends with silicone compound (6850-00-
295-7685) and wrap with barrier (8135-00-226-
3124), secure with tape (7510-00-266-6716).
(c) Apply a coating of silicone compound (6850-00-295-
7685) to battery terminals.
(d) Secure cover batteries with lumber strips (5510-
00-220-6078) and steel strapping (8135-00-283-
0669) and strapping seals (8135-00-239-5293).
Change 1
B-2-86
|