TM 43-0156
Step
Function
Mech
Insp
4
d.
Let the battery stand for 30 minutes and then check the
cont.
specific gravity of each cell with a hydrometer. Cor-
rect the reading to 800F (27 ) by adding 0.004 for each
C
10 above 80 and subtracting 0.004 for each 10
F
F
F
below 80 .
F
e.
You should charge the battery if the specific gravity of
any cell measures below 1.270 after correcting to 80
F
(27 ).
C
NOTE
If any of the cells cannot
be charged to a specific
gravity of at least 1.270,
the battery is not accept-
able for this application.
f.
Replace the vent caps when you have completed the above.
5
Flush fuel lines with VV-F-800 diesel fuel prior to starting
engine.
6
RETAIN ALL SHIPPING CONTAINERS FOR RETURN
SHIPMENTS.