TM 43-0156
Step
Function
Mech
Insp
3
(3) Rack breakers into place. Block and brace to
cont
prevent movement.
(4) Pack fuses from each cabinet as follows:
(a)
Wrap fuses with barrier (8135-00-226-3124) and place
in plastic bags (8105-00-902-6508) according to
rating. Heat seal or staple bags. Mark bags with
ratings of fuses.
(b)
Place bagged fuses in a fiberboard box (12 x 12 x 4).
(c)
Secure each box to the bottom of each cabinet with
tape (7510-00-916-9659). NSN 7510-00-890-9875
may be used as a substitute.
(5) Coat electrical contacts and terminals with coating
compound (6850-00-003-5295).
f.
Batteries and Cables.
NOTE
The batteries are on both sides of the engine under the decking
on the electric start generator set. The batteries for the air start
generator set are on one side ony.
l
(1) Disconnect battery cables and remove the batteries.
(2) Clean and dry the batteries and battery holder.
(3) Install the batteries and connect jumper cables.
Preserve terminals with silicone (6850-00-295-7685).
(4) Preserve the positive and ground cable connectors with
silicone (6850-00-295-7685), cover with barrier (8135-
00-224-8885), and seal with tape (7510-00-266-6715).
Secure the cables to the frame with tape (7510-00-916-
9659). NSN 7510-00-890-9875 may be used asa
substitute for 7510-00-916-9659.
g.
Fire Extinguisher. Lock fire extinguisher in bracket and
secure with wire (9505-00-222-3829).
Change 1