TM 43-0156
Step
Function
Mech
Insp
3
(3) Drive Belts and Pulleys.
cont
(a)
Remove drive belts.
(b)
Paint unpainted surface of pulley grooves with primer
(c)
Install belts but do not tighten.
(d)
Prepare tag (8135-00-292-2345) indicating "BELT
TENSION RELIEVED, ADJUST PRIOR TO STARTING."
(e)
Attach tag to compressor.
d.
Air Tanks (two).
(1) Remove access decking.
(2) Open drain valves.
(3) Remove pressure relief valves.
(4) Atomize spray interior surfaces of tanks with preservative
oil (9150-00-111-0209).
(5) Install pressure relief valves.
(6) Leave drain valves open.
Generator Control Cabinet and High Voltage Compartment.
e.
(1) Remove relay covers and place barrier (8135-00-226-
3124) between disk and magnets. Set the protective
relay time dial settings to zero. Install and secure the
relay covers with wire (9505-00-222-3829).
(2) If circuit breakers are Westinghouse, remove and pack
arc chutes in original containers.
(a)
Wrap the arc chutes with cushioning (8135-00-855-
6969).
(b)
Place three arc chutes into each box.
(c)
Isolate the arc chutes from the sides of the box and
each other with 2 x 4 lumber (5510-00-220-6194).
(d)
Seal box.
B-1-27
|