TABLE 2-3. AIR FORCE LOGISTICS CENTER DEPOT OAP EVALUATION CRITERIA
(Follow ALC Depot Decision Logic When Guidance Are Exceeded.)
JOAP ATOMIC EMISSION
Fe
Ag
Al
Cr
Cu
Mg
Ni
Si
Ti
4
4
-
5
6
-
-
J33
16
4
3
5
3
3
5
3
-
J57-13/21/23
11
3
5
3
3
3
5
3
-
J57-19/29
11
3
3
5
3
3
5
3
-
J57-43/55/59
11
3
4
4
2
2
4
-
-
J75
9
3
3
5
3
3
7
3
-
J79
19
3
2
2
3
3
3
2
15
F100
5
2
2
4
3
3
4
3
-
TF30-P3/7/9
7
2
2
4
3
2
4
2
-
TF30-P100
7
2
5
5
3
3
5
3
-
TF33-P3/5/9/11A
10
3
5
5
3
3
5
3
-
TF33-P7/7A/100A
10
3
2
2
3
5
6
3
25
TF39
9
3
3
4
3
8
4
3
-
TF41-A-1
12
3
3
4
3
5
4
3
-
TF41-A-2
12
3
1
1
12
1
2
1
5
T56-7/9/15
(1)
2
1
1
1
1
1
2
1
4
G56-7/9/15
(1)
2
1
6
4
-
6
7
-
-
T58-3/5
21
4
-
6
4
5
5
-
-
T64
12
3
3
2
5
6
5
3
25
GTC85-70
10
2
3
2
3
6
4
3
25
GTC85-71
8
1
2
2
2
6
2
2
25
GTCP85-108
5
2
-
3
4
3
6
3
3
25
GTCP85-180
10
25
4
3
3
2
8
4
4
GTCP85-397
12
25
-
2
2
2
3
4
3
GTCP165-1
6
25
3
1
5
4
6
6
2
T41M-9
50
(1)  Use difference between preliminary sample and acceptance sample. Change oil when Si level exceed 20